ForHosting KIT · Developer Utilities

Interior Wall Surface Temperature Calculator

This interior wall surface temperature calculator estimates how cold the room-side face of a wall becomes during heating conditions.

● BetaFree · in your browser
Use it from WebAPIEmailTelegramApp soon

Enter the indoor air temperature, the wall U-value, the inside film heat-transfer coefficient, and the indoor-to-outdoor temperature difference. The result helps you compare the predicted surface temperature with the indoor dew point, which is the practical test for surface condensation. It also reports heat flux, the inside-film temperature drop, the implied outdoor temperature, and a dimensionless temperature factor for transparent engineering checks.

What the calculated surface temperature means

A room may feel comfortably warm while a poorly insulated wall remains much colder than the indoor air. Heat flowing through the wall crosses a thin boundary layer of relatively still air at the inside face. That layer creates a temperature drop between the room air and the physical surface. The calculator determines steady heat flux as the wall U-value multiplied by the indoor-to-outdoor temperature difference. It then divides that heat flux by the inside film coefficient to obtain the room-side film drop, and subtracts the drop from the indoor temperature. The resulting interior surface temperature is the value to compare with the indoor dew point. If the surface is warmer than the dew point, liquid condensation is not predicted under the entered steady conditions. If it is equal to or colder than the dew point, moisture can condense. Because relative humidity or dew point is not one of the four inputs, the calculator does not invent a pass or fail result. It provides the thermal value needed for an honest condensation assessment.

Choose inputs that describe the same condition

Use an indoor air temperature in degrees Celsius and a non-negative temperature difference defined as indoor temperature minus outdoor temperature. Celsius degree differences and kelvin differences have the same numerical size, so either convention works for the difference. The U-value must represent the complete wall assembly, including all layers and relevant surface resistances according to the method used in your project. Enter the inside film coefficient in watts per square metre-kelvin. It depends on heat-flow direction, surface orientation, air movement, and the standard or design method being followed; it is not a universal material property. Keep all inputs from the same design case. Combining a winter design temperature difference with a U-value or film coefficient based on incompatible assumptions can create a precise-looking but misleading answer. The calculator rejects zero or negative thermal coefficients, non-finite numbers, negative heating-season differences, and a U-value greater than the inside film coefficient because those values do not form a physically consistent resistance model for this calculation.

Assess condensation risk and understand the limits

First calculate or measure the indoor dew point from indoor temperature and relative humidity, then compare it with the reported interior surface temperature. A positive margin, with the surface warmer than the dew point, indicates no surface condensation under the assumed steady state. A small margin deserves caution because humidity, outdoor temperature, air movement, furnishings, and workmanship vary over time. Corners, thermal bridges, window reveals, structural penetrations, and areas behind cabinets can be colder than the one-dimensional clear-wall estimate. The method also assumes steady heat transfer and does not model thermal storage, rain, solar gain, air leakage, moisture diffusion, or intermittent heating. Use the heat-flux and film-drop outputs to audit the arithmetic, and use the temperature factor to compare cases that have different indoor and outdoor temperatures. For design approval, mold analysis, or investigation of an occupied building, supplement this screening calculation with measured humidity, thermal-bridge analysis, suitable safety margins, and the requirements of the applicable building standard. The API price is $0.002 per calculation, while the same deterministic calculation can run in the browser.

Screen a wall retrofit

Compare the estimated room-side surface temperature before and after an insulation upgrade under the same winter design condition.

Investigate a cold interior finish

Turn a known wall U-value and temperature difference into a surface estimate that can be checked against site measurements and dew point.

Check an engineering calculation

Verify heat flux, inside-film temperature drop, and temperature factor with an explicit deterministic result.

What equation is used?

Heat flux is U multiplied by the indoor-to-outdoor temperature difference. The inside-film drop is heat flux divided by the inside film coefficient, and the surface temperature is indoor temperature minus that drop.

Does this calculator determine the dew point?

No. Relative humidity is not an input. Calculate or measure the indoor dew point separately, then compare it with the reported surface temperature.

When is surface condensation possible?

Surface condensation is possible when the indoor-air dew point is equal to or higher than the interior surface temperature.

Can I enter the temperature difference in kelvins?

Yes. A temperature difference has the same numerical magnitude in kelvins and degrees Celsius. The indoor temperature itself is entered in degrees Celsius.

Why must the U-value not exceed the inside film coefficient?

The complete wall conductance cannot exceed the conductance of one resistance that is already part of its heat-flow path. Such an input would imply an inconsistent resistance model.

Does the result include thermal bridges?

Only if the U-value and modelling assumptions represent them appropriately. A one-dimensional clear-wall value usually does not predict colder corners, junctions, or penetrations.

Everything on this page is available programmatically. This section is for teams who want to wire it into their own systems; everyone else can just use the tool above.

POSThttps://api.kit.forhosting.com/eng/wall-surface-temp

Prefer to automate it? One authenticated POST creates the task; the result comes back by webhook or a signed link. The same capability also runs here on the web, by email and from Telegram — and soon from our app too.

curl -X POST https://api.kit.forhosting.com/eng/wall-surface-temp \
  -H "Authorization: Bearer $KIT_KEY" \
  -H "Content-Type: application/json" \
  -d '{"indoor_temperature":21,"u_value":0.35,"inside_film_coefficient":7.7,"temperature_difference":25}'
{
  "indoor_temperature": 21,
  "u_value": 0.35,
  "inside_film_coefficient": 7.7,
  "temperature_difference": 25
}
{
  "task_id": "tsk_a1b2c3d4e5f6a1b2c3d4e5f6",
  "type": "eng.wall_surface_temp",
  "status": "queued",
  "_links": {
    "result": "/tasks/tsk_…/result"
  }
}

The API is asynchronous: the call returns a task_id immediately and the result arrives by webhook. Polling is capped at 1 req/s per task.

Per request$0.002

Published price — no tokens, no invented credits. A failed task is never charged.

HTTPCodeMeaning
401unauthorizedMissing or invalid API key.
402insufficient_balanceYour balance doesn't cover the task price.
404unknown_typeThat task type doesn't exist.
429rate_limitedToo many requests. Use the webhook instead of polling.

Read the full KIT documentation →